PRODUCT

  • Heatless Regeneration Compressed Air Dryer
  • Heatless Regeneration Compressed Air Dryer
  • Heatless Regeneration Compressed Air Dryer
  • Heatless Regeneration Compressed Air Dryer

Heatless Adsorption Air Dryer

Capacity range : 2~200 m3/min
Pressure range : 0.4~1.0MPa (4~10barg)
Max. inlet temperature : 50 ℃
Max. ambient temperature : 45 ℃
Power supply : 220V/1Ph/50Hz or 60Hz
PDP : -20 ℃ , -40 ℃ , -70 ℃

Rated condition :
Working pressure : 0.7Mpa
Inlet temperature : 38 ℃
Ambient temperature : 38 ℃
PDP : -20 ℃

Other :
Regeneration air consumption < 14%

Reliable Design
Supportive Ceramic Balls used at the bottom of adsorption tower make uniform air-flow distribution , in this way ,desiccant can be protected from soaking and also get longer service life , together with special designed stainless steel flow divider , pressure loss can be greatly reduced.
Special designed high performance desiccant can get best dew point.
A full range of standard configuration for high performance pneumatic valve, when it's running, reliability and pressure loss are significantly better than the film valve, solenoid valve.
Configuring multiple protection of electric heater, greatly improving the reliability. Standard gas control valve control with high efficiency oil, dust filter.

Various control options
Standard configuration is using reliable PLC controller.
Optional Siemens and ABB brand PLC or touch screen and etc.
We can meet various customer requirements for communication, connecting RS485 I/O , Profibus or Modbus to Ethernet.

Energy-saving
LDCS-Load Dependent Control System ensure the case that performance is best and at the meantime to control the purge air loss accurately , compared with fixed cycle time control type ,LDCS could save at least 8% comprehensive energy consumption.
DPOS-Dew Point Operation System can delay adsorption time under unstable load, DPOS could save at least 75% comprehensive energy consumption.
(LDCS: Load Dependent Control System)
(DPOS: Dew Point Operation System)

Technical Specification

Model Capacity Installed
Power (kW)
Demension  mm Weight
(kg)
Air
Connection
Recommended
Pre-Filter Model
Recommended
After-Filter Model
m³/min CFM L W H
RSXW-20 2 71 0.2 779 549 1788 198 DN25 RSG-AA-0058G/V2 RSG-AR-0058G/V2
RSXW-30 3 106 0.2 839 549 1703 325 DN25 RSG-AA-0058G/V2 RSG-AR-0058G/V2
RSXW-60 6 212 0.2 1060 618 2020 510 DN40 RSG-AA-0145G/V2 RSG-AR-0145G/V2
RSXW-80 8 282 0.2 1060 618 2020 520 DN40 RSG-AA-0145G/V2 RSG-AR-0145G/V2
RSXW-100 10 353 0.2 1200 738 1824 585 DN50 RSG-AA-0220G/V2 RSG-AR-0220G/V2
RSXW-120 12 424 0.2 1200 738 1824 600 DN50 RSG-AA-0220G/V2 RSG-AR-0220G/V2
RSXW-150 15 530 0.2 1200 733 2028 680 DN50 RSG-AA-0330G/V2 RSG-AR-0330G/V2
RSXW-200 20 706 0.2 1500 914 1973 870 DN65 RSG-AA-0330G/V2 RSG-AR-0330G/V2
RSXW-250 25 883 0.2 1530 962 2056 975 DN65 RSG-AA-0430G/V2 RSG-AR-0430G/V2
RSXW-300 30 1059 0.2 1630 1199 2019 1150 DN80 RSG-AA-0620G/V2 RSG-AR-0620G/V2
RSXW-350 35 1236 0.2 1790 1207 2049 1275 DN80 RSG-AA-0620G/V2 RSG-AR-0620G/V2
RSXW-400 40 1412 0.2 1830 1232 2059 1350 DN80 RSG-AA-0620G/V2 RSG-AR-0620G/V2
RSXW-500 50 1766 0.2 2012 1293 2238 1600 DN100 RSG-AA-0830F/V2 RSG-AR-0830F/V2
RSXW-600 60 2119 0.2 2150 1321 2518 2100 DN100 RSG-AA-1000F/V2 RSG-AR-1000F/V2


Rated Conditions Working Range Avaliable
Working pressure : 0.7MPag / 100psig Max. working pressure : 1.0MPag / 145psig Higher pressure above 1.0MPag / 145psig
Inlet temp : 38 ℃ / 100 ℉ Max. inlet temperature : 50 ℃ / 122 ℉ PDP -20℃ / -4 ℉ and -70℃ / -100 ℉
Ambient temp : 38℃ / 100 ℉ Max. ambient temperature : 40℃ / 104 ℉ Higher capacity
PDP:-40 ℃ / -40 ℉ Stainess steel vessel or piping
GB,ASME,PED,etc. vessels

Correction Factors

Actual Capacity (m³/min) = Nominal Capacity × KA × KB

Working Pressure (KA) Mpag 0.5 0.6 0.7 0.8 0.9 1.0
psig 73 87 100 116 131 145
CFP 0.87 0.94 1.00 1.06 1.12 1.17


Inlet Temperature (KB) 35 38 40 42 45 50
95 100 104 108 113 122
CFT 1.18 1.00 0.90 0.81 0.69 0.58